Sector applications
Sector experience. One delivery standard.
01
Commercial
Office buildings & retail
- Addressable fire detectionMulti-zone panels with remote monitoring and BMS integration
- Clean-agent suppressionFM-200 / Novec 1230 for server rooms and electrical panels
- Emergency lighting & exit signageSelf-test luminaires, maintained and non-maintained circuits
- CCTV & access controlIP camera networks, card-reader entry, visitor management
NBC 2016 Part 4, BIS IS 2189, NFPA 72 — compliant design and commissioning documentation supplied.
02
Industrial
Factories, warehouses & logistics
- High-sensitivity smoke detectionVESDA aspirating systems for dusty or high-airflow environments
- Deluge & foam suppressionFor flammable liquid stores, paint booths and transformer bays
- Perimeter security & CCTVLong-range PTZ cameras, thermal imaging, fence-intrusion detection
- AMC & maintenance contractsScheduled inspection, testing and 24 × 7 breakdown response
NFPA 13, TAC / PESO guidelines, Factory Act compliance — full documentation and third-party inspection support.
03
Government
Institutional & public-sector buildings
- Conventional & addressable detectionScalable panel architecture for large multi-wing complexes
- Wet-pipe & pre-action sprinklersDesigned to NBC and CPWD specifications
- Biometric access controlFingerprint and face-recognition terminals, audit-trail logging
- Integrated command & controlCentral monitoring station with alarm management software
CPWD guidelines, NBC 2016, BIS IS 15908 — GFR-compliant procurement documentation available.
04
Healthcare
Hospitals & diagnostic centres
- Analogue addressable fire alarmZoned to ward, OT and ICU areas with nurse-call integration
- Medical-grade suppressionInert-gas systems for MRI, server and pharmacy areas
- Emergency lighting3-hour maintained luminaires on all escape routes and stairwells
- IP CCTV & patient safetyCorridor, entrance and car-park surveillance with NVR recording
NABH fire-safety requirements, NBC 2016 Part 4, NFPA 99 healthcare facilities standard.
05
IT & Data Centres
Technology campuses & server rooms
- VESDA very-early-warning detectionSub-floor and above-ceiling sampling for raised-floor data halls
- Inert-gas total-flooding suppressionIG-541 / IG-55 systems — no residue, safe for occupied spaces
- Precision access controlMulti-factor authentication, man-trap airlocks, server-cage locking
- 24 × 7 remote monitoringAlarm transmission to central station with escalation protocols
TIA-942, NFPA 75 / 76, Uptime Institute Tier design criteria — documentation for audit and insurance.
Get in touch