Emergency Lighting

Emergency Lighting & Exit Signage Systems

Maintained and non-maintained luminaires, central battery systems, and photoluminescent exit signage — designed and installed to NBC Part 8, BIS IS 1944, and BS 5266 for safe evacuation in any emergency.

Why it matters

Why Emergency Lighting Matters

When mains power fails during a fire or emergency, occupants must be able to evacuate quickly and safely. Emergency lighting is not optional — it is a statutory requirement under the National Building Code of India (NBC 2016 Part 8) for all commercial, industrial, and public buildings.

Locus Fire & Security designs, supplies, installs, and maintains complete emergency lighting systems — from individual self-contained luminaires to large central battery installations serving hundreds of fittings across multi-storey complexes.

1 lux
Minimum illuminance
on escape route floor
3 hrs
Battery autonomy
minimum per NBC Part 8
Monthly
Self-test interval
functional test required
Annual
Full discharge test
compliance certification
Systems & solutions

What We Supply & Install

Maintained Emergency Luminaires

3-hour rated, self-test capable

Remain illuminated at all times and automatically switch to battery backup during mains failure. Required in cinemas, theatres, hospitals, and all public assembly areas where continuous illumination is mandatory.

Applications:Cinemas, theatres, hospitals, public assembly halls, shopping malls
Standards:BIS IS 1944 | NBC Part 8 | BS 5266-1

Non-Maintained Emergency Luminaires

3-hour rated, automatic self-test

Activate only on mains failure, remaining off during normal operation. The standard solution for most commercial and industrial buildings where continuous illumination is not required by regulation.

Applications:Offices, warehouses, factories, retail premises, educational buildings
Standards:BIS IS 1944 | NBC Part 8 | BS 5266-1

Central Battery Systems

2–8 hour autonomy, up to 500 luminaires

A single centralised battery bank powers all emergency luminaires in the building. Simplifies testing, maintenance, and compliance reporting compared to managing hundreds of individual self-contained units.

Applications:Hospitals, airports, large commercial complexes, government buildings, data centres
Standards:BIS IS 1944 | NBC Part 8 | BS 5266-2

Exit & Escape Route Signage

Photoluminescent and LED-backlit

Clearly marked escape routes with directional signage compliant with NBC and IS standards. Photoluminescent versions require no power source and remain visible for hours after illumination is removed.

Applications:All occupied buildings — offices, factories, hospitals, hotels, schools
Standards:BIS IS 12062 | NBC Part 8 | ISO 7010

High-Risk Task Area Lighting

Anti-panic, minimum 0.5 lux at floor level

Dedicated emergency lighting for areas where sudden darkness creates a specific hazard — machinery rooms, electrical switchgear, plant rooms, and process areas. Provides sufficient illumination to safely shut down operations.

Applications:Machinery rooms, switchgear rooms, plant rooms, server rooms
Standards:BIS IS 1944 | EN 1838 | NBC Part 8

Emergency Lighting AMC

Quarterly testing, annual full-duration test

Scheduled maintenance covering lamp and battery replacement, self-test log review, full 3-hour discharge testing, and compliance certification. Keeps your system audit-ready at all times.

Applications:All installed emergency lighting systems
Standards:NBC Part 8 | BS 5266-1 Clause 12
Our process

From Survey to Certification

01

Site Survey & Lux Calculation

We assess escape routes, floor areas, and risk zones to calculate the minimum illuminance levels required under NBC and IS 1944.

02

System Design & Specification

Selection of luminaire type (maintained/non-maintained/central battery), battery duration, and signage placement — documented in a full design drawing set.

03

Supply & Installation

Supply of BIS-approved luminaires and signage, installed by our certified technicians with minimal disruption to building operations.

04

Commissioning & Testing

Full 3-hour discharge test, self-test verification, and lux level measurement at all escape route points. Compliance certificate issued on completion.

05

AMC & Ongoing Compliance

Quarterly maintenance visits, annual full-duration testing, and compliance documentation to keep your system audit-ready year-round.

Compliance

Standards We Design To

NBC 2016 Part 8

National Building Code — lighting and ventilation requirements for all building types

BIS IS 1944

Indian Standard for emergency and exit lighting systems

BS 5266-1

British Standard for emergency lighting — code of practice for non-residential premises

BS 5266-2

British Standard for central battery systems

ISO 7010

International standard for safety signs including evacuation route signage

BIS IS 12062

Indian Standard for photoluminescent safety markings

Sectors served

Buildings We Work In

Commercial Offices & IT Parks
Hospitals & Healthcare
Industrial & Manufacturing
Government & Institutional
Hotels & Hospitality
Educational Institutions

Need Emergency Lighting for Your Building?

Our team will survey your premises, design a compliant system, and provide a detailed specification and quote — at no obligation.