Fire Suppression Systems

Fire Suppression Systems — Design, Supply & Installation

Wet pipe, dry pipe, pre-action, deluge, foam, clean agent, CO₂, water mist, and kitchen hood suppression systems. Engineered to NBC, NFPA, and TAC standards. Supply, installation, commissioning, and AMC across India.

Our approach

The Right Suppression System for Every Hazard.

No two fire risks are identical. A server room demands a clean agent that leaves no residue; a paint shop needs foam; a cold-store needs dry pipe. Locus surveys the hazard, selects the correct suppression technology, designs the hydraulic system to code, and installs it — from pump room to the last sprinkler head.

Every system we deliver is hydraulically calculated, third-party inspected, and handed over with full as-built drawings, test certificates, and an AMC plan. We supply equipment from Minimax, Tyco, Ceasefire, Viking, and HD Fire — and manufacture our own Locus-branded sprinkler heads and accessories for cost-effective mid-range projects.

10
Suppression technologies
Wet, dry, foam, gas, mist & more
800+
Systems installed
Across NCR and India
6
Approved brands
Minimax, Tyco, Viking & more
100%
Hydraulically calculated
IS 15105, NFPA 13, TAC
Systems & solutions

Suppression Systems We Design & Install

Wet Pipe Sprinkler Systems

IS 15105 / NFPA 13 — fastest response, lowest cost

The most widely installed suppression system worldwide. Pipes are permanently charged with water; heat from a fire opens the nearest sprinkler head and water discharges immediately. Ideal for occupied buildings where ambient temperatures stay above 4°C year-round.

Applications:Office buildings, hospitals, hotels, retail malls, warehouses, educational institutions
Brands:Minimax, Tyco, Viking, Locus

Dry Pipe Sprinkler Systems

IS 15105 / NFPA 13 — for sub-zero or unheated spaces

Pipes are charged with pressurised air or nitrogen instead of water. When a sprinkler head opens, air pressure drops and the dry pipe valve releases water into the system. Eliminates freeze risk in cold stores, parking structures, and unheated warehouses.

Applications:Cold storage, unheated warehouses, car parks, loading docks, outdoor canopies
Brands:Minimax, Viking, Tyco

Pre-Action Sprinkler Systems

NFPA 13 — dual-interlock for water-sensitive areas

A two-step system: water only enters the pipes after a fire detection signal AND a sprinkler head opens. Dual-interlock pre-action prevents accidental discharge — critical in data centres, archives, and museums where water damage is as catastrophic as fire.

Applications:Data centres, server rooms, archives, museums, telecom exchanges
Brands:Minimax, Viking, Tyco

Deluge Systems

NFPA 15 / TAC — simultaneous discharge across entire zone

All sprinkler heads in the zone are open at all times; water is held back by a deluge valve. On detection, the valve opens and the entire zone is flooded simultaneously. Used where fire spreads rapidly and a single-head response would be too slow.

Applications:Aircraft hangars, transformer bays, paint shops, flammable liquid storage, conveyor tunnels
Brands:Minimax, Viking, HD Fire

Foam Suppression (AFFF / AR-AFFF)

NFPA 11 / OISD-117 — flammable liquid and hydrocarbon fires

Aqueous Film Forming Foam (AFFF) and Alcohol-Resistant AFFF blanket flammable liquid surfaces, cutting off oxygen and preventing re-ignition. Delivered via foam chambers, monitors, deluge systems, or fixed pourers depending on the hazard geometry.

Applications:Fuel storage tanks, oil terminals, petrochemical plants, aviation fuel facilities, solvent stores
Brands:Minimax, Tyco, HD Fire

Clean Agent Suppression (Novec 1230 / FM-200)

NFPA 2001 / ISO 14520 — zero residue, safe for occupied spaces

Gaseous suppression agents — 3M Novec 1230 and FM-200 (HFC-227ea) — extinguish fires by absorbing heat without leaving residue or damaging sensitive equipment. Safe for occupied spaces at design concentration. Ideal where downtime and equipment loss are unacceptable.

Applications:Data centres, server rooms, UPS rooms, control rooms, telecom exchanges, medical equipment rooms
Brands:Minimax, Tyco, Ceasefire

CO₂ Suppression Systems

NFPA 12 / IS 15683 — total flooding and local application

Carbon dioxide suppression for total flooding of enclosed machinery spaces and local application on specific hazards. Highly effective on Class B and C fires. Requires strict safety interlocks and evacuation procedures — not suitable for normally occupied spaces.

Applications:Printing presses, turbine enclosures, generator rooms, paint booths, dip tanks
Brands:Minimax, Ceasefire, HD Fire

Water Mist Systems

NFPA 750 — high-pressure fine droplets, minimal water damage

High-pressure water mist systems discharge fine droplets that cool the flame, displace oxygen, and reduce radiant heat — using up to 90% less water than conventional sprinklers. Effective on Class A, B, and C fires with minimal collateral water damage.

Applications:Heritage buildings, hotels, hospitals, marine vessels, turbine halls, museums
Brands:Minimax, Tyco

Kitchen Hood Suppression Systems

NFPA 96 / UL 300 — wet chemical, automatic gas shut-off

Wet chemical suppression systems designed specifically for commercial cooking equipment. Nozzles are positioned over fryers, griddles, and range hoods; on activation, wet chemical agent is discharged and the gas supply is automatically shut off to prevent re-ignition.

Applications:Commercial kitchens, hotel restaurants, hospital canteens, food courts, cloud kitchens
Brands:Ceasefire, Minimax, Tyco

AMC & Maintenance

Half-yearly inspections, hydraulic retesting, TAC compliance

Scheduled maintenance covering sprinkler head inspection and replacement, pump room testing, valve exercise, pressure gauge calibration, and foam concentrate sampling. We maintain systems supplied by us and third-party-installed systems alike, and provide TAC compliance documentation.

Applications:All installed suppression systems — own-supply and third-party
Brands:Brand-agnostic service
Approved brands

Brands We Supply & Support

MinimaxGerman engineering — global suppression leader
TycoJohnson Controls — NFPA-listed components
CeasefireIndian manufacturer — clean agent & CO₂
VikingUS-listed sprinkler heads & valves
HD FireIndian manufacturer — TAC-approved
LocusOwn-brand sprinkler heads & accessories
Our process

From Hazard Survey to TAC Certification

01

Hazard Survey & Risk Classification

We classify the occupancy, identify fuel loads, map drainage constraints, and review existing infrastructure before selecting a suppression technology.

02

Hydraulic Design & Code Compliance

Full hydraulic calculations to IS 15105, NFPA 13/15, or TAC requirements. Pump sizing, pipe schedules, and sprinkler density maps — all client-approved before procurement.

03

Supply of Listed Equipment

All components sourced from authorised distributors. TAC-listed, UL-listed, or FM-approved as required by the authority having jurisdiction.

04

Installation & Commissioning

Pipe fabrication, installation, hydrostatic testing, pump commissioning, and full system acceptance test witnessed by the client and, where required, the TAC inspector.

05

Handover, Certification & AMC

As-built drawings, test certificates, TAC inspection report, and a structured AMC programme to keep the system compliant and operationally ready.

Compliance

Standards We Design To

IS 15105

Indian Standard for design and installation of fixed automatic sprinkler fire extinguishing systems

NFPA 13

Standard for the installation of sprinkler systems — wet, dry, pre-action, and deluge

NFPA 11

Standard for low-, medium-, and high-expansion foam systems

NFPA 2001 / ISO 14520

Clean agent fire extinguishing systems — Novec 1230, FM-200, and inert gas

NFPA 12

Carbon dioxide extinguishing systems — total flooding and local application

NFPA 750

Standard on water mist fire protection systems

NBC Part 4

National Building Code of India — fire and life safety, suppression requirements

TAC / OISD-117

Tariff Advisory Committee and Oil Industry Safety Directorate requirements for industrial suppression

Sectors served

Industries We Work In

Commercial Offices & IT Parks
Industrial & Manufacturing
Oil, Gas & Petrochemical
Data Centres & Server Rooms
Hospitals & Healthcare
Warehousing & Logistics
Government & Institutional
Hospitality & Retail

Need a Suppression System Designed to Code?

Share your building type and hazard profile — our engineers will recommend the right system and provide a hydraulic design proposal at no obligation.